Braided gland packings — PTFE, graphite, aramid and lubricated grades — that seal rotating and reciprocating shafts in pumps and valves.

Coils of braided gland packing in PTFE, graphite and aramid beside a valve stem
Gland Packing
Braided compression packing for shaftsSERIES 03 / 08
Capabilities

Performance envelope

Gland packing remains the workhorse seal for valve stems and general-service pumps, and the braid you choose decides how long the gland goes between adjustments. SealGuard packings are densely braided from high-grade yarns with the right lubricant and corner reinforcement for the duty — low-friction PTFE for chemicals, flexible graphite for high-temperature steam, tough aramid for abrasive slurry. The result is controlled leakage, lower stem friction and far fewer trips to the gland follower.

Operating LimitsGland Packing
Temperatureθ · °C
-200°C to +650°C
PressureP · bar
Up to 300 bar (valve service)
Size RangeDN · ⌀
3 mm – 25 mm square section · spools & pre-cut rings
MaterialsMAT
PTFE, flexible graphite, aramid, PTFE/graphite blend, lubricated synthetic
Product Range05 LINES

Gland Packing lines

Browse the gland packing range, compare the headline limits, and add candidates straight to your quote request.

Coil of white braided PTFE gland packing on a spoolLow-friction chemical-service braid

PTFE Packing

Densely braided PTFE gland packing that seals chemical pumps and valves with low shaft friction and near-universal chemical resistance.

Temp
-200°C to +260°C
Pressure
Up to 150 bar (valve) · 20 bar (rotary pump)
Specs
Coil of black graphite gland packing with reinforced cornersHigh-temperature fire-safe braid

Graphite Packing

Flexible-graphite and carbon-yarn gland packing for high-temperature steam and valve service, with API 622/589 fire-safe credentials.

Temp
-200°C to +650°C (steam)
Pressure
Up to 300 bar (valve service)
Specs
Coil of yellow aramid gland packing for abrasive slurry serviceAbrasion-resistant slurry braid

Aramid Packing

Tough aramid-fibre gland packing engineered to resist extrusion and abrasion in slurry, sand-laden and high-pressure pump service.

Temp
-100°C to +280°C
Pressure
Up to 200 bar (reciprocating) · 25 bar (rotary)
Specs
Coil of grey PTFE-graphite blended gland packingDual-action rotary pump braid

PTFE Graphite Packing

PTFE / graphite blended packing that combines low friction with heat dissipation for high-speed rotary pump shafts.

Temp
-200°C to +280°C
Pressure
Up to 100 bar (valve) · 20 bar (rotary pump)
Specs
Coil of soft pale lubricated fibre gland packingSelf-lubricating soft-fibre braid

Lubricated Packing

Soft, PTFE-impregnated fibre packing pre-charged with break-in lubricant for clean-water, food and general low-duty pump service.

Temp
-30°C to +150°C
Pressure
Up to 25 bar (valve) · 12 bar (rotary pump)
Specs
Specification Guidance

Getting the spec right

Field-tested guidance from our engineers on specifying gland packing for demanding service.

  • Note 01

    Match packing cross-section to the stuffing-box depth and fit a full ring count for even compression.

  • Note 02

    Choose flexible graphite for high-temperature steam and heat-transfer service where PTFE softens.

  • Note 03

    Use aramid corners or rings to resist extrusion in abrasive slurry and high-pressure pump duties.

  • Note 04

    Allow a controlled drip on rotary pumps — over-tightening burns the packing and scores the shaft.

Field Evidence

Proven where it matters

A reliability problem in the field, closed at the joint — and the numbers that followed.

Process pump fitted with a cartridge mechanical seal in a chemical plantCase Study
Chemical

From six-week pump failures to a year between interventions

01
Challenge

An aggressive acid-transfer service was destroying pump seals roughly every six weeks. Each failure meant an emergency strip-down, lost batch time and a growing reliability backlog across a bank of duty/standby pumps.

02
Solution

We replaced the component seals with balanced cartridge mechanical seals running silicon-carbide faces and PTFE-encapsulated secondary seals, plus a flush plan matched to the duty. The cartridge format removed setting error on rebuild and gave the technicians a repeatable installation.

03
Result

Mean time between failures moved from six weeks to over twelve months on the lead pumps, and mean time to repair dropped because the cartridge drops straight in. The site redeployed the maintenance hours it used to spend rebuilding seals.

8x
MTBF improvement
60%
Lower mean time to repair
12+ mo
Run length on lead pumps
Let’s specify it