The engineering behind the seal.
Specification guides, material-selection matrices and the answers our engineers give every day — the working knowledge behind a joint that holds. Shortlist with the references, confirm against the datasheet, and send us the conditions when a duty sits near a limit.
- Guides
- 03
- References
- 02
- FAQ sets
- 01
Engineering guides
Step-by-step routines for specifying, installing and selecting seals the way our engineers do.
How to specify a gasket
A five-step routine for turning a flange and a service condition into a complete, orderable gasket specification — and avoiding the omissions that cause leaks.
Read the guideGasket installation & bolt-up best practice
Most flange leaks are assembly faults, not material faults. This guide covers the preparation, torque pattern and re-check routine that make a joint seal first time.
Read the guideSelecting a mechanical seal
How to move from a leaking pump to the right mechanical seal — covering balance, arrangement, face materials and flush plan, the four decisions that set reliability.
Read the guideReference matrices
Engineered envelopes and selection matrices to sanity-check a choice before you reach the datasheet.
Sealing material selection matrix
A first-pass guide to matching seal materials to temperature, pressure and media. Use it to shortlist candidates, then confirm against the product datasheet and your service conditions.
Open the referenceTemperature & pressure compatibility
Indicative service envelopes by seal family, to sanity-check a selection before you reach the datasheet. Treat the limits as practical guidance, not certified ratings.
Open the referenceAnswers
Plain, practical answers to the questions our specification desk fields most often.
Match the material to the duty.
A first-pass guide to matching seal materials to temperature, pressure and media. Use it to shortlist candidates, then confirm against the product datasheet and your service conditions.
Scroll the matrix horizontally to read every column
Answers from the specification desk
The questions we field most often, with the practical answer — material choice, torque, documentation and lead times.
It comes down to motion. Use a gasket for static, bolted flange joints; gland packing or a mechanical seal for rotating or reciprocating shafts. Gland packing is robust, repairable and tolerant of misalignment but allows a small controlled leak; a mechanical seal costs more up front but runs leak-free and is the right choice for hazardous, volatile or emission-controlled fluids.
A spiral-wound gasket interleaves a metal winding (typically 316L) with a soft filler such as graphite or PTFE, giving excellent recovery, a very wide temperature and pressure envelope, and resilience under thermal cycling — ideal for critical high-class flange joints. A compressed-fibre (CNAF) gasket is a soft, cut sheet suited to general-purpose, lower-class duty where cost and easy fabrication matter more than extreme conditions.
Flexible graphite is the workhorse for superheated steam, in both gasket and packing form, with a practical envelope to around +550°C. For critical steam flanges, a graphite-filled spiral-wound gasket adds the recovery needed to survive thermal cycling. Protect graphite from strong oxidising media, and confirm the specific pressure class on the datasheet.
PTFE has near-universal chemical resistance across the full pH range, which makes it the default for aggressive and mixed chemical service. Its limitations are mechanical, not chemical: it cold-flows (creeps) under sustained load and has a ceiling around +260°C. For demanding joints use a filled or expanded PTFE construction, or a PTFE-envelope gasket, to control creep.
Across the range, from cryogenic LNG service near -196°C up to roughly +650°C for metallic gaskets, and from vacuum up to 420 bar / Class 2500 on the highest-rated flange joints. No single material spans all of that — and a material rarely delivers its maximum temperature and maximum pressure at the same time. Tell us your worst-case condition and we'll specify to it.
Use the gasket's seating-stress-based torque from the datasheet, applied with a calibrated wrench and known thread lubrication, in a cross pattern over at least three passes. Generic 'as tight as it'll go' bolt-up is the most common cause of flange leaks — both over- and under-torquing damage the joint. Re-torque soft and spiral-wound gaskets after they settle and, for hot service, after the first thermal cycle.
Yes. Alongside standard catalogue items we die-cut and machine bespoke gaskets, sheets and seals to drawing or sample, including odd-form covers, large-diameter and one-off heat-exchanger gaskets. Send a drawing, the flange details or a physical sample together with the service conditions and we'll quote the right material and construction.
We supply water-approved and FDA 21 CFR-compliant grades — typically EPDM and silicone elastomers and specific PTFE compounds — for potable water, food, beverage and pharmaceutical contact. Compliance depends on the exact compound, so request the food- or water-grade variant and we'll provide the supporting documentation with the order.
As standard, orders carry material identification and traceability. On request we provide material certificates (including EN 10204 3.1 where applicable), compliance statements for PED/CE, FDA, ATEX and fire-safe duties, and recommended installation data such as bolt torque sequences. Specify the documentation you need on the enquiry so it's prepared with the parts.
Standard catalogue items and common cut gaskets generally ship from stock within a few working days. Engineered items — spiral-wound and metallic gaskets, cartridge mechanical seals and bespoke die-cut parts — are made to order, with lead time depending on material and quantity. For turnaround and breakdown support we can expedite; flag the required date on your enquiry and we'll confirm against it.
Still narrowing the spec?
Send us the service conditions — media, temperature, pressure and motion — and our engineers will return a specific recommendation with predicted performance.
